Copyright RetroZone inc.2012 

ZONE CONTROL ACCESSORIES

Solenoid


The sturdy three-way switches used in the Airzone solenoid panel connect to the

vacuum and pressure side of the, pump while the common port connects to the field damper tubing.  Normally open or normally closed operation is field-selectable by reversing the

tubing connections.  Each SOL can inflate one or more Flexdampers.  ALL Flexdampers

tied to a solenoid will open and close simultaneously.
Specs: 24V operated at about .33 amps. 4.5"x2.5'" x 3"

Used as replacement or expansion.
Airzone solenoid

 Solenoid -- $64.00
ADC_uploaded_button.gif 

 VC_uploaded_button.gif


Expansion Pump

 

NEW!  EP-2 Super Duty Expansion Pump

 

 

Introducing our new EP-2 Expansion pump with more powerful vacuum and pressure to insure you get the best performance from your Airzone SPP and SPP-SD Panels.  The pump contains two internal 24VAC relays designed to operate the pump in conjunction with the HVAC blower and furnace.  Two diaphragms give a redundant action for extra long life.  One pump should provide adequate airflow for most applications, except where a large number and/or very large Flexdampers are used.  If more damper speed is needed, order an additional pump.  The pump is designed  for wall mounting next to the solenoid panel and operates whenever the fan, AC or furnace is in operation.  Please note:  When you order our SPP or SPP-SD Panel, one pump is included.

 

Use Airzone SPP-SD Panels with round and rectangular Flexdampers™.  Airzone™ Solenoid Panels are compatible with any conventional zone control system that supports two-position, 24vac dampers.  This includes, but is not limited to most Zone Control panels made by Honeywell, Durozone, Durodyne, EWC, Aprilaire, Lennox, RCS, Ecojay, Robert Shaw, Zone Perfect and Jackson Controls.



EP-2 Expansion Pump

$145.00
Add To Cart 
View Cart

 

 

 

EP-1 Expansion Pump


The pump used with the SPP panel is a long lasting, continuous duty pump that provide both a source of pressure and a source of vacuum. The pump contains two internal 24VAC relays designed to operate the pump in conjunction with the HVAC blower and furnace.  Two diaphragms give a redundant action for extra long life.  One pump should provide adequate airflow for most applications, except where a large number and/or very large Flexdampers are used.  If more damper speed is needed, order an additional pump.  The pump is designed for wall mounting next to the solenoid panel.
Specs: 3.5"x6"x2.5", about 2 lbs. 11O VAC with 24 VAC interface

Airzone Expansion Pump

 Expansion Pump -- $75.50
ADC_uploaded_button.gif

VC_uploaded_button.gif



Transformers


40VA Plug in transformer use on all zone control systems. Fuse protected, screw terminals.  ALSO COMES IN HARDWIRE AND 75VA.

Specs: 3.5"x2.75"x2.25, about 1 lb.  24VAC, 40VA, 1.7 AMP

 

 

 

 

 

 

 

40 Va Plug In Transformer -- $19.74
ADC_uploaded_button.gif   

                 40 Va HARDWIRE Transformer -- $19.00                   

Add To Cart  

75 Va HARDWIRE Transformer -- $41.95
ADC_uploaded_button.gif

VC_uploaded_button.gif



PLENUM TUBING


Plenum Tubing
120' roll, 3/8 o.d., 1/4 i.d. Plenum Tubing -- $34.00
ADC_uploaded_button.gif

PRODUCT: 250' roll, 3/8 o.d., 1/4 i.d. Plenum Tubing -- $56.00
ADC_uploaded_button.gif

VC_uploaded_button.gif

Fire Rated Connect Tape
Ten yards of special heat activated tape for joining ends of round

Flexdampers, not needed for rectangular Flexdampers

.
PRODUCT: Fire Rated Connect Tape -- $11.95

 Add To Cart

 VC_uploaded_button.gif

               View Cart

ECL Evaporator Control Limit Switch


RetroZone's popular ECL switch is a great, low cost, low refrigerant temperature switch that prevents AC coil freeze up.  Frozen coils can be caused by improper refrigerant charge, dirty filters, malfunctioning dampers, burned out fans, and many other reasons.  The ECL switch snaps on the suction line at the evaporator coil, and has a simple two wire connection that can wire in series to the "Y" compressor circuit.  At 38° F refrigerant suction line temperature, the contacts open to offline the compressor, and does not reset until 50° F. Flutter-proof snap acting switch will not short cycle compressor, and can also be used to open all dampers on a zoning system. Great protection, great price, and well proven.
Specifications: About l"xl"x2" with bracket., 15 AMP contacts

.
Evaporator Control Limit Switch -- $13.00
ADC_uploaded_button.gif

VC_uploaded_button.gif

SecurityMetrics for PCI Compliance, QSA, IDS, Penetration Testing, Forensics, and Vulnerability Assessment